WADiana compact analyser offers total automation in immunohematology with safety and flexibility in pre-transfusion analyses
Product features:
Fully automated with maximum safety features for continuous and integrated automatic process for incubation, centrifugation, reading and interpretation of results.
High on flexibility and adaptability with easy to operate software
DIANA READER
Exclusive reader for the reading and interpretation of Grifols DG Gel® cards
Product features:
Twin reader for DG Gel® cards and micro-plates.
Accessory for reading the results and recording data in the system software.
Makes emergency sample management more flexible when connected to the DG Gel Processor
Positive identification of samples and regents by bar code.
DG THERM
Digital incubator for the manual processing of Grifols DG Gel® cards.
Product features:
2 independent incubation zones with a capacity for 12 DG Gel® cards and 12 test tubes in
each zone
Digital user interface screen for control and visualization of remaining incubation time and real temperature for each zone
Fixed pre-set temperature of 37 ºC
Pre-set incubation time of 15 minutes, which can be adjust by the user
Audible programmable alarm to notify end of incubation period
Visual and audible indication of any errors and power failure
Quick procedure guide included
Removable trash bin
DG SPIN
Digital centrifuge for the manual processing of Grifols DG Gel® cards.
Product features:
Simultaneous centrifuge of up to 24 DG Gel® cards.
Removable and exchangeable spinning head.
Pre-defined centrifugal parameters for optimum DG Gel® cards processing: acceleration, speed, braking and time.
Digital user interface visor for control and visualization of centrifuge speed and time remaining for processing.
Programmable audible alarms for end of centrifugal time periods.
Visual and audible indication of any error situation and power failure.
Imbalance system detects incorrect placing of DG Gel® cards on the spinning head.
Quick procedure guide included.
DG GEL® ABO/Rh
Profile: A-B -AB D- CDE -Ctrl-N/a1-N/b Technique :Determination of the antigens of the Abo and Rh (D) system and determination of the reverse ABO group.
Number of tests/cards:1Presentation: 4x12 cards
DG GEL® ABO/CDE
Profile: A-B-C-D-E-Ctrl -N/a1-N/b Technique:Determination of the antigens of the ABO and Rh (D,C,E)
system and determination of the reverse ABO group.
Number of tests/cards:1 Presentation: 4x12 cards
DG GEL® ABO/Rh (2D)
Profile: A-B-AB-D-D-Ctrl -N/a1-N/b Technique :Determination of the antigens of the ABO and Rh(D) System and determination of the reverse ABO group.
Number of tests/cards:1 Presentation: 4x12 cards
DG GEL® Confirm
Profile: A-B-D-CTRl-A-B-Ctrl Technique : Confirmation of the blood groups of the ABO and Rh (D) system.
Number of tests/cards:1 Presentation: 4x12 cards
DG GEL® Anti-D
Profile:4x (D-Ctrl) Technique: Determination of the Rh (D)
Number of tests/cards:4 Presentation: 1x12 cards
DG GEL® Rh
Profile:C-c-E-e-C-c-e Technique: Determination of the antigens of the Rh system.
Number of tests/cards:2 Presentation: 4x12 cards
DG GEL® Rh + Kell
Profile:D'-C -Cw -c-E-e-Kell-Ctrl Technique: Determination of the blood groups of the ABO system
Number of tests/cards:1 Presentation: 4x12 cards
DG GEL® AB (x4)
Profile:4x (A-B) Technique:Determination of the blood groups of the ABO system.
Number of tests/cards:4 Presentation: 4x12 cards
DG GEL® Coombs
Profile:8x (AHG) Technique:Indirect Coombs and Direct Coombs tests.The indirect Coombs tests
inclide screening and identification of unexpected antibodies, crossmatch tests,
autocontrol and red blood cell typing.
Number of tests/cards: depending on the test. Presentation: 4x12 cards
DG GEL®Neutral
Profile: 8x (N) Technique:Saline and enzymatic tests. The salina and enzymatic technique tests
include : screening and identification of unexpected antibodies, crossmatch tests,
autocontrol, red blood cell typing and determination of the reverse ABO group.
Number of tests/cards: depending on the test. Presentation: 4x12 cards
DG GEL® Neutral/Coombs
Profile:N-N-N-N-AHG-AHG-AHG Technique:Indirect and Direct Coombs tests, physics medium for saline and
enzymatic tests, The tests include: screening and identification of unexpected
antibodies, crossmatic tests, autocontrol and red blood cell typing .
Number of tests/cards: depending on the test. Presentation: 4x12 cards
DG GEL® Anti-lgG
Profile:8x (lgG) Technique:Indirect Coombs and Direct Coombs tests, the Indirect Coombs tests
include screening and identification of unexpected antibodies, crossmatch tests,
autocontrol and red blood cell typing.
Number if tests/ cards: depending on the test. Presentation: 4x12 cards
DG GEL® CT
Profile:A-B-D'-Ctrl -N-N- AHG -AHG Technique:Confirmaton of the antigens of the ABO and Rh (D) systems, ABO/rh compatibility test, screeing of unexpected antibodies, croomatch and autocontrol.
Number of tests/ cards:1 Presentation: 4x12 cards
DG GEL® DC Scan
Profile:2x (AHG-lgG-CD3-Ctrl) Technique:Evaluation of positive Direct Coombs samples. It allows differentiating
red blood cell sensitized "in vivo" by lgG type immunogloulins or the complement C3d fraction.
Number of tests/ cards:2 Presentation: 1x12 cards
DG GEL® DC Scan
Profile: A-B-AB-D-D'-Ctrl-lgG-AHG Technique:Determination of the antigens of the ABO and Rh (D)
system and Direct Coombs test in newbooms.
Number of tests/ cards:1 Presentation: 4x12 cards
DG GEL® Grifols Red Blood Cells
Grifols red blood cells for revese group determination, screening and identification of unexpected antibodies, and quality control.
DG GEL®Auxiliary Reagents And Solutions
Solutions diluents and other reagents that complete the Grifols 1H reagents system
copyright
, Span Healthcare Private Limited. All rights reserved.